When it comes to air quality monitoring, precision and reliability are non-negotiable. The Met One Particle Counter stands as a leading instrument in aerosol measurement, delivering highly accurate particle counting for industries ranging from pharmaceutical cleanrooms to environmental research. In this comprehensive guide, we explore every critical aspect of the Met One Particle Counter, including its technical specifications, advanced features, applications, and benefits.
Introduction to the Met One Particle Counter
The Met One Particle Counter is a cutting-edge device designed to detect and quantify airborne particles with exceptional precision. Manufactured by MET ONE Instruments, a trusted name in particle measurement technology, this instrument is widely used in HVAC systems, cleanroom validation, industrial hygiene, and environmental monitoring.
With real-time data logging, superior sensitivity, and robust construction, the Met One Particle Counter ensures compliance with ISO 14644-1, EU GMP, and FDA regulations. Whether for research, manufacturing, or regulatory compliance, this device provides unmatched accuracy in particle analysis.
Key Features of the Met One Particle Counter
The Met One Particle Counter is packed with innovative features that set it apart from competitors. Below, we highlight the most critical functionalities:
1. High-Precision Laser Detection Technology
- Utilizes a high-sensitivity laser diode for 0.3 μm to 25 μm particle detection.
- Six customizable size channels for tailored particle analysis.
- ±5% counting accuracy ensures reliable data for critical applications.
2. Real-Time Data Logging & Reporting
- Built-in memory stores thousands of samples for extended monitoring.
- USB and Bluetooth connectivity for seamless data transfer.
- Compatible with Met One’s Aerocet software for automated reporting.
3. Rugged & Portable Design
- Lightweight and ergonomic for field use.
- Shock-resistant casing ensures durability in harsh environments.
- Long-lasting battery (up to 8 hours of continuous operation).
4. Compliance with Industry Standards
- Meets ISO 21501-4 calibration standards.
- Validated for FDA, EU GMP, and ISO 14644-1 compliance.
- NIST-traceable calibration for unmatched reliability.
Detailed Technical Specifications
To fully understand the capabilities of the Met One Particle Counter, we break down its technical specifications below:
Parameter | Specification |
---|---|
Particle Size Range | 0.3 μm – 25 μm |
Flow Rate | 0.1 CFM (2.83 L/min) |
Counting Efficiency | 50% at 0.3 μm, 100% at 0.45 μm |
Channel Configuration | 6 user-selectable channels |
Data Storage | Up to 10,000 samples |
Battery Life | 8 hours (rechargeable Li-ion) |
Operating Conditions | 10°C to 40°C, 0-95% RH (non-condensing) |
Dimensions | 7.5 x 4.3 x 2.5 inches |
Weight | 1.5 lbs (0.68 kg) |
Applications of the Met One Particle Counter
The versatility of the Met One Particle Counter makes it indispensable across multiple industries:
1. Pharmaceutical & Cleanroom Monitoring
- Ensures compliance with ISO Class 1 to ISO Class 9 cleanrooms.
- Validates HEPA filter integrity in sterile manufacturing environments.
2. HVAC & Indoor Air Quality (IAQ) Testing
- Monitors particulate levels in commercial buildings, hospitals, and schools.
- Identifies contaminant sources for improved ventilation strategies.
3. Environmental & Occupational Safety
- Measures airborne pollutants in industrial workplaces.
- Assesses compliance with OSHA and NIOSH exposure limits.
4. Research & Academia
- Supports aerosol studies in environmental science and engineering.
- Provides high-resolution data for scientific publications.
Why Choose the Met One Particle Counter Over Competitors?
Several factors make the Met One Particle Counter the preferred choice for professionals:
✔ Superior Accuracy – Laser-based detection ensures minimal false counts.
✔ Regulatory Compliance – Fully compliant with global air quality standards.
✔ User-Friendly Interface – Intuitive touchscreen for easy operation.
✔ Long-Term Reliability – Durable construction backed by industry-leading support.
The Ultimate Particle Counting Solution
The Met One Particle Counter is a top-tier instrument for precise airborne particle analysis. With advanced laser detection, real-time data logging, and industry-leading compliance, it is the ideal choice for pharmaceutical, environmental, and industrial applications.
Met One vs TSI Particle Counters: Which One Wins?
When it comes to high-precision particle counting, two industry-leading brands dominate the market: Met One Instruments and TSI Incorporated. Both manufacturers produce top-tier aerosol measurement devices, but which one truly outperforms the other? In this comprehensive comparison, we analyze key specifications, accuracy, usability, compliance, and real-world performance to determine the ultimate particle counter for cleanroom monitoring, environmental research, and industrial hygiene.
Understanding Particle Counters: Why Accuracy Matters
Particle counters are critical for monitoring air quality, ensuring cleanroom compliance, and detecting contaminants in controlled environments. The Met One and TSI brands are widely recognized for their advanced laser detection, reliable data logging, and adherence to ISO standards. However, subtle differences in technology, calibration, and user experience can significantly impact performance.
Below, we break down each brand’s strengths and weaknesses to help you make an informed purchasing decision.
Head-to-Head Comparison: Met One vs TSI Particle Counters
1. Technology & Detection Accuracy
Met One Particle Counters
- Use high-sensitivity laser diodes with 0.3 μm to 25 μm detection range
- Six customizable size channels for tailored analysis
- ±5% counting accuracy, meeting ISO 21501-4 standards
- NIST-traceable calibration for regulatory compliance
- Feature advanced optical sensors with 0.1 μm to 10 μm detection range (varies by model)
- Up to 16 size channels for granular data analysis
- ±3% counting accuracy in high-end models (e.g., TSI 9306)
- ISO 21501-4 and JIS B 9921 compliance
Verdict:
- TSI offers superior resolution for sub-micron particles (critical for pharmaceuticals)
- Met One provides better durability in harsh industrial environments
2. Data Logging & Software Integration
Met One
- Built-in memory stores 10,000+ samples
- Aerocet software for automated reporting and trend analysis
- USB and Bluetooth connectivity options
TSI
- Larger internal memory (up to 50,000 samples in premium models)
- TSI AeroTrak software with advanced statistical tools
- Wireless data transfer and cloud integration capabilities
Verdict:
- TSI provides more advanced data management solutions
- Met One offers simpler, more straightforward software for basic monitoring
3. Build Quality & Portability
Met One
- Rugged, shock-resistant casing
- Lightweight (typically under 2 lbs)
- IP rating varies by model (typically IP50)
TSI
- Premium aluminum housing in professional models
- Some bulkier designs for enhanced durability
- Higher IP ratings available (up to IP65 in certain models)
Verdict:
- Met One wins for field portability
- TSI offers better protection in extreme conditions
4. Compliance & Industry Standards
Both brands meet critical industry standards including:
- ISO 14644-1 (Cleanroom classification)
- EU GMP Annex 1
- FDA regulatory requirements
- NSF/ANSI 49 (Biosafety cabinets)
Key Differences:
- TSI offers more comprehensive documentation packages
- Met One provides simpler validation protocols

Industry-Specific Recommendations
Pharmaceutical & Biotechnology Applications
For sterile manufacturing and USP 797 compliance, TSI’s higher resolution (0.1μm detection) makes it the preferred choice for most pharmaceutical applications.
HVAC & Building Monitoring
Met One’s rugged design and straightforward operation make it ideal for routine building air quality assessments and filter testing.
Research & Academic Use
TSI’s advanced data analysis capabilities better serve research applications requiring detailed particle characterization.
Industrial Hygiene & Workplace Safety
Met One’s durability and simple interface work best for routine industrial hygiene monitoring.
Price Comparison & Value Proposition
Entry-level models:
- Met One: 3,500−3,500−5,000
- TSI: 4,500−4,500−7,000
Professional-grade models:
- Met One: 6,000−6,000−10,000
- TSI: 8,000−8,000−15,000
While TSI commands a 20-30% price premium, the investment is justified for applications requiring:
- Sub-micron detection
- Advanced data analytics
- Stringent compliance documentation
Final Verdict: Which Particle Counter Should You Choose?
Choose TSI if you need:
✔ Ultra-fine particle detection (below 0.3μm)
✔ Advanced data management features
✔ Comprehensive compliance documentation
✔ Research-grade precision
Choose Met One if you prioritize:
✔ Field durability and portability
✔ Simpler operation and maintenance
✔ Cost-effective monitoring solutions
✔ Industrial environment performance
Both brands offer excellent particle counting solutions, but the optimal choice depends entirely on your specific application requirements and budget considerations.
How to Calibrate Your Met One Particle Counter
Proper calibration of your Met One particle counter is essential for maintaining measurement accuracy, ensuring regulatory compliance, and extending the lifespan of your equipment. In this comprehensive guide, we provide detailed instructions on how to calibrate Met One particle counters, including pre-calibration checks, step-by-step procedures, and post-calibration validation.
Why Calibration Matters for Met One Particle Counters
Regular calibration ensures your Met One particle counter delivers precise and reliable data, which is critical for:
- Cleanroom certification (ISO 14644-1, EU GMP Annex 1)
- Pharmaceutical manufacturing compliance (FDA, USP <797>)
- HVAC system performance validation
- Environmental monitoring accuracy
Without proper calibration, your device may produce false readings, leading to failed audits, product contamination risks, or regulatory violations.
Pre-Calibration Checklist
Before beginning the calibration process, ensure you have:
- A certified calibration aerosol (e.g., PSL spheres)
- A zero-count filter (HEPA or ULPA)
- A flow meter (to verify 2.83 L/min or 0.1 CFM flow rate)
- A Met One calibration adapter (if required for your model)
- The latest firmware installed (check Met One’s website)
- A stable environment (temperature: 20-25°C, humidity: 30-60% RH)
Read; Best Supplier of Cleanroom Particle Counters | Choose TOPTEC.PK
Step-by-Step Calibration Procedure
1. Perform a Zero Count Test
- Attach a HEPA/ULPA filter to the inlet
- Power on the device and let it stabilize for 10 minutes
- Start a zero count test (typically 1-2 minutes)
- Verify results – counts should be ≤1 particle per cubic foot for ISO compliance
2. Verify Flow Rate Accuracy
- Connect a calibrated flow meter to the particle counter
- Run the flow verification mode
- Adjust if necessary using manufacturer-specified methods
- Record the final flow rate (must be within ±5% of 0.1 CFM)
3. Calibrate Particle Size Channels
- Generate a stable aerosol cloud using PSL spheres
- Connect the calibration adapter (if required)
- Run the automatic calibration sequence
- Verify each size channel’s response against NIST-traceable standards
- Save calibration coefficients to the device memory
4. Perform a Post-Calibration Verification
- Test with a secondary reference aerosol
- Compare results to expected values
- Document all calibration data for quality records
Calibration Frequency Recommendations
We recommend the following calibration intervals:
- Routine calibration: Every 12 months for standard use
- Critical applications: Every 6 months (pharmaceuticals, cleanrooms)
- After any impact or repair: Immediate recalibration required
Common Calibration Mistakes to Avoid
- Using expired or contaminated calibration aerosols
- Skipping environmental stabilization time
- Improper handling of the flow meter
- Failing to document calibration results
- Ignoring manufacturer-specific requirements
Met One Calibration Service Options
For users who prefer professional calibration services, Met One offers:
- Factory recalibration programs
- On-site calibration services
- NIST-traceable certification
- Comprehensive calibration reports
Troubleshooting Calibration Issues
If your calibration fails, check these common issues:
- Clogged inlet or flow path
- Low battery power
- Outdated firmware
- Damaged laser optics
- Improper aerosol generation
Maintaining Calibration Integrity
To extend time between calibrations:
- Store properly in a clean, dry environment
- Handle carefully to avoid impacts
- Clean regularly following manufacturer guidelines
- Verify performance with periodic checks
Conclusion: Ensuring Ongoing Accuracy
Proper Met One particle counter calibration is not just a regulatory requirement – it’s a critical quality assurance practice. By following this detailed calibration guide, you can maintain measurement precision, comply with industry standards, and maximize your equipment’s performance.
For optimal results, we recommend:
✔ Following the manufacturer’s guidelines precisely
✔ Maintaining detailed calibration records
✔ Investing in professional services when needed
✔ Implementing a regular calibration schedule